Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2021 · Paper 1 · Q4(c)(i) · p.6
Optical pyrometer and thermocouple pyrometer;
Marking scheme
Optical pyrometer The optical pyrometer method compares the intensity of light from the filament of a lamp with the colour from the furnace. Current flow from the lamp can be adjusted, using a variable resistor, to match the light from the furnace. There are three possible results with the optical pyrometer: filament too bright, filament not bright enough and filament matching the furnace colour. When the filament seems to 'disappear', the temperature of the filament matches that of the furnace and a reading can thus be taken. [Diagram: Optical pyrometer setup showing object, optical lenses, filter, filament, power source with scale. Three comparison images of filament brightness relative to furnace colour: 'too low', 'correct', 'too high'.] The thermocouple pyrometer works on the principle that different metals conduct heat at different speeds. Two dissimilar metals usually, nickel-aluminium and nickel-chromium, are joined together with a galvanometer placed at the cold junction. A rise in temperature at the hot junction produces an electrical current which is recorded by the galvanometer. This galvanometer is calibrated to read in degrees of temperature rather than indicating electrical units. [Diagram: Thermocouple pyrometer setup showing a hot junction of two dissimilar metals connected to a galvanometer.]