Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (3)
2024 · Paper 1 · Q1(c) · p.3
In precision measurement, explain what is meant by parallax error.
Marking scheme
Parallax error arises when a change of viewpoint results in an inaccurate reading. Measurements need to read perpendicular to the measuring scale. [Diagram showing three lines of sight to a ruler: one perpendicular, two at angles. The perpendicular sight line indicates a reading of 6.0 cm, while the angled sight lines indicate 6.2 cm and 6.5 cm, with the angled ones marked with crosses.] (5)
2018 · Paper 1 · Q3(c) · p.6
Describe, with the aid of a diagram(s), one method of measuring furnace temperature, using the following guidelines: Equipment used, Principles of operation, Accuracy of results.
Marking scheme
Thermocouple Pyrometer: Principle of operation: Two dissimilar metals are joined together with a galvanometer placed at the cold junction. A rise in temperature at the hot junction produces an electrical current which is recorded by the galvanometer. This galvanometer is calibrated to read in degrees of temperature rather than indicating electrical units. This is a very accurate way to measure furnace temperature. [Diagram: Shows a thermocouple pyrometer with a hot junction and a cold junction connected to a galvanometer. Labels indicate 'Hot Junction', 'Cold Junction', 'Dissimilar metals', 'Galvanometer'.] OR Optical pyrometer: this method compares the intensity of light from the filament of a lamp. Current flow from the lamp can be adjusted, using a variable resistor, to match the light from the furnace. When the filament seems to 'disappear', a temperature reading can be taken. Accuracy will depend on the visual accuracy of the operator. [Diagram: Shows an optical pyrometer with a filament bulb, variable resistor, and eyepiece, aimed at a furnace glass. Below are three views of the filament against the furnace background, labelled 'Too low', 'Correct', 'Too high'.]
2016 · Paper 1 · Q3(c) · p.6
A thermocouple pyrometer as shown opposite, is used to accurately measure furnace temperature during heat treatment. [Image: Thermocouple pyrometer]. (i) Explain, with the aid of a diagram(s), the principle of operation of a thermocouple pyrometer. (ii) Name and describe one alternative method of measuring furnace temperature.