Past exam questions (1)
2021 · Paper 1 · Q3(c)(i) · p.5
Describe, with the aid of suitable diagrams, the stages involved in liquid penetrant testing. [Visual aid: Image: a close-up of a surface with visible indications from liquid penetrant testing.]
Marking scheme
Liquid penetrant testing: A coloured or fluorescent dye, when applied to a clean surface and allowed to dwell for 10 to 20 minutes, will be drawn into the flaw by capillary pressure. The excess dye is then removed from the surface and a developer applied. The developer assists in drawing the dye back out to the surface by giving good visual contrast. After a time, usually a minimum of 10 minutes, the surfaces are visually inspected. White light is used for red dyes, ultra-violet light for fluorescent dyes. [Diagram: Three stages of liquid penetrant testing showing dye penetrating a surface crack, excess dye being removed, and a developer being applied.] (8)