Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (4)
2024 · Paper 1 · Q5(b) · p.3
On your drawing show how to prevent moisture penetration at the window cill. [Visual aid: vertical section through an external wall and window cill]
Marking scheme
Show how to prevent moisture penetration at the window cill. DPC and drip (4 marks). [Diagram: Detail of a window cill showing DPC and drip.] Any other suitable detail will be accepted.
2024 · Paper 1 · Q5(a) · p.3
To a scale of 1:5, draw a vertical section through the external wall and the bottom of the window. Show the typical construction details from a level 400 mm below, to a level 300 mm above, the concrete window cill. Include three typical dimensions on your drawing. [Diagram: A vertical section through an external wall and a window cill, showing construction details.]
Marking scheme
Draw a vertical section through the external wall and the bottom of the window. Any 8 x 5 marks. [Diagram: Vertical section through an external wall and window, showing construction details.] Specification – typical detail: 19 mm external render, Concrete block outer leaf 100 mm, Full fill insulated cavity 200 mm, Wall tie, Concrete block inner leaf 100 mm, 15 mm internal plaster, Cavity closer, DPC, Precast concrete cill, Throating / drip, Window board, Airtightness tape, Window frame 120 mm x 80 mm, Triple glazing. Note: Any alternative detailing which complies with current Building Regulations is acceptable.
2021 · Paper 1 · Q5(a) · p.3
To a scale of 1:5, draw a vertical section through the external wall and bottom portion of the window. Show the typical construction details from a level 400 mm below to a level 300 mm above the concrete window cill. Include three typical dimensions on your drawing. [Visual aid: Diagram of a triple glazed wooden window in a wall]
Marking scheme
Draw a vertical section through external wall and bottom of window. (Part (a) Sub-total 35 marks) Concrete block outer leaf (5 marks) Full filled insulated cavity (5 marks) Wall ties (5 marks) Concrete block inner leaf (5 marks) 13 mm internal plaster and 19 mm external render (5 marks) Cavity closer (5 marks) DPC (5 marks) Precast concrete window cill with throating / drip (5 marks) Window board (5 marks) Airtight tape (5 marks) Window frame 120 mm x 80 mm (5 marks) Triple glazing (5 marks) Any 7 x 5 marks (Sub-total 35 marks) Any three typical dimensions (3 marks) Draughting, accuracy and scale (excellent, good, fair) (8, 6, 4 marks) (Sub-total 11 marks)
2017 · Paper 1 · Q5(a) · p.3
A triple-glazed wooden casement window, as shown, is fixed in a 400 mm external concrete block wall with a full-fill insulated cavity. The fixed frame of the window is 100 mm x 80 mm and is thermally broken. The wall is rendered on both sides. [Diagram: A cross-section of a wall with a window.] To a scale of 1:5, draw a vertical section through the external wall and bottom portion of the window, showing the fixed frame of the window and the concrete cill. Show the typical construction details from 300 mm below to a level 250 mm above the concrete cill. Include three typical dimensions on your drawing.
Marking scheme
Vertical section through external, cill and bottom portion of window frame. Details - typical sizes. Reinforced concrete window cill: 4 marks. Damp proof course (dpc) wrapped around window cill: 4 marks. 19 mm external render: 4 marks. 100 mm concrete block outer leaf: 4 marks. Wall tie: 4 marks. Full-fill cavity insulation: 4 marks. Proprietary cavity closer: 4 marks. 100 mm concrete block inner leaf: 4 marks. 15 mm internal plaster with skim coat: 4 marks. Window board: 4 marks. 100 mm x 80 mm thermally broken fixed frame of window: 4 marks. Triple glazing with low e glass: 4 marks. Any 9 of the above details (4 marks each): Sub-total 36 marks. Three typical dimensions: 3 marks.