Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2018 · Paper 1 · Q1(a) · p.2
To a scale of 1:5 draw a vertical section through the strip foundation, the 215 mm wall, the ground floor and the centre of the door up to a point 500 mm above finished floor level. Show 600 mm width of floor on each side of the wall and include three typical dimensions on your drawing. [Visual aid: Diagram: cross-section of a wall with foundation and floor]
Marking scheme
15 mm internal plaster with skim coat (5 marks) 120 x 50 mm doorframe (5 marks) 60 mm flush panel door (5 marks) 65 x 15 mm architrave and 100 x 15 mm skirting board (5 marks) 20 mm tongue and groove floating hardwood floor (5 marks) 100 mm smooth concrete floor (5 marks) 250 mm floor insulation with thermal blocks (5 marks) 200 mm concrete sub-floor (5 marks) Radon barrier (5 marks) 30 mm sand blinding (5 marks) 200 mm hardcore (5 marks) Reinforced concrete foundation (5 marks) 215 mm concrete block wall (5 marks) Any 7 of the above details (5 marks each) (Sub-total 35 marks) Any three typical dimensions (3 marks)