Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (8)
2024 · Paper 1 · Q1(b) · p.2
On your drawing, show how the wallplate is secured to the external wall. [Visual aid: cross-section of a pitched roof eaves and wall]
Marking scheme
Wall plate strap. [Diagram: Detail showing how a wall plate is secured to the external wall using a strap.] Wallplate strap clearly identified (4 marks).
2024 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the external wall of the house and through the eaves of the trussed roof. On your drawing, show the typical construction details from a level 400 mm below the wallplate, through the wall and eaves of the roof. Include the first three courses of slate at eaves. Include three typical dimensions on your drawing. [Diagram: A cross-section of a pitched roof eaves and wall, showing prefabricated trussed rafters, concrete block wall, insulation, battens, breather membrane, and slates.]
Marking scheme
Any 7 x 5 marks. [Diagram: Vertical section through the eaves of a roof showing prefabricated trussed rafters, insulation, wall construction, and roof finish.] Specification – typical detail: 19 mm external render, Concrete block outer leaf 100 mm, Full fill insulated cavity 200 mm, Wall tie, Concrete block inner leaf 100 mm, 15 mm internal plaster, Cavity closer, 100 mm × 75 mm wall plate, Prefabricated roof truss 200 mm x 50mm, Airtight membrane/tape, Plasterboard with skim coat, Ventilation, Soffit, Fascia, Tilting fillet, Breather membrane, Battens 50 mm x 30 mm, Slates. N.B. Any alternative detailing which complies with current Building Regulations is acceptable.
2023 · Paper 1 · Q4(b) · p.3
Using notes and a freehand sketch, show the typical construction details of how a trussed rafter is secured on the external wall of a house. Include the following in your sketch: external wall, wallplate, trussed rafter, nail plate, truss clip. [Visual aid: Sketch of a roof of a house under construction using prefabricated trussed rafters.]
Marking scheme
external wall sketch & note (4 + 2 marks) (6 marks) wallplate sketch & note (4 + 2 marks) (6 marks) trussed rafter sketch & note (4 + 2 marks) (6 marks) nail plate sketch & note (4 + 2 marks) (6 marks) truss clip sketch & note (4 + 2 marks) (6 marks) (Sub-total 30 marks)
2023 · Paper 1 · Q4(a) · p.3
Discuss two advantages of using prefabricated trussed rafters to construct a roof. [Visual aid: Sketch of a roof of a house under construction using prefabricated trussed rafters.]
Marking scheme
Advantage 1 (4 marks) Advantage 2 (4 marks) (Sub-total 8 marks)
2021 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the external wall and through the eaves of the pitched roof. On your drawing, show the typical construction details from a level 400 mm below the wallplate, through the wall and eaves. Include the first three courses of slate at eaves. Include three typical dimensions on your drawing. [Visual aid: Diagram of roof eaves construction]
Marking scheme
Slates 600 mm x 300 mm on battens 50 mm x 30 mm (5 marks) Breather membrane (5 marks) Rafters 200 mm x 50 mm (5 marks) Ceiling joist with insulation between joists (5 marks) Insulated plasterboard with skim coat (5 marks) Wallplate 100 mm x 75 mm (5 marks) Airtight membrane and tape (5 marks) Ventilation (5 marks) Tilting fillet, fascia, soffit and eaves gutter (5 marks) Concrete block inner leaf (5 marks) Full fill cavity insulation 200 mm, wall ties and cavity closer (5 marks) Concrete block outer leaf (5 marks) 13 mm internal plaster and 19 mm render (5 marks) Any 7 x 5 marks (Sub-total 35 marks) Any three typical dimensions (4 marks) Draughting, accuracy and scale (excellent, good, fair) (8, 6, 4 marks) (Sub-total 12 marks)
2020 · Paper 1 · Q5(a) · p.3
To a scale of 1:5, draw a vertical section through the roof at the ridge. Show the typical construction details from the top of the ridge to a level 100 mm below the collar ties. The collar ties are positioned 900 mm below ridge level. Include three courses of slate at the ridge. Include three typical dimensions on your drawing. [Diagram: A cross-section of a pitched roof at the ridge.]
Marking scheme
Ridge tile (5 marks) Ridge vent (5 marks) Roofing slates (5 marks) Battens 50 mm x 35 mm (5 marks) Breather membrane (5 marks) Ridge board 275 mm x 32 mm (5 marks) Rafter 200 mm x 50 mm (5 marks) Collar tie 200 mm x 50 mm (5 marks) Insulation between rafters (5 marks) Airtight membrane (5 marks) Insulated plasterboard (5 marks) Plaster skim (5 marks) Any 7 x 5 marks (Sub-total 35 marks) Any three typical dimensions 3 x 1 mark (3 marks) Draughting, accuracy and scale (excellent, good, fair) (8 marks) Sub-total 11 marks
2015 · Paper 1 · Q1(a) · p.2
A front porch with a tiled roof is shown in the sketch. The porch has an internal width of 2.0 metres. The roof of the porch, which is insulated, is a traditional cut roof and has a pitch of 30°. The roof is supported on a 400 mm concrete block wall with a 200 mm full-fill insulated cavity. The rafters and ceiling joists are 200 mm × 40 mm. Insulated plasterboard is also fixed to the underside of the ceiling joists. To a scale of 1:5, draw a vertical section through one half of the roof of the porch, to show one rafter length. Show the typical construction details from a level 400 mm below the wallplate, through the wall and eaves up to the ridge. Show three courses of tiles at eaves. Include four typical dimensions. [Sketch: A cross-section of a porch roof showing a tiled roof, rafters, ceiling joists, wallplate, concrete block wall, and eaves detail.] Note: It is not necessary to show the front door. [Visual aid: Sketch: A cross-section of a porch roof showing a tiled roof, rafters, ceiling joists, wallplate, concrete block wall, and eaves detail.]
Marking scheme
Ridge board 250 mm × 35 mm (4 marks) Concrete tiles (4 marks) Softwood battens 44 mm × 35 mm (4 marks) Vapour diffuse/Breather membrane overlapped and taped (4 marks) Rafters 200 mm × 40 mm @ 450 mm centres (4 marks) Roof insulation to comply with current building regulations – min 200 mm (4 marks) Ceiling joists 200 mm × 40 mm @ 450 mm centres (4 marks) Insulated plasterboard with skim coat (4 marks) 100 mm × 75 mm double wallplate fixed to blockwork (4 marks) 15 mm internal plaster with hardwall finish (4 marks) Concrete block inner leaf 100 mm (4 marks) Full-fill insulated cavity - 200 mm (4 marks) Concrete block outer leaf 100 mm (4 marks) 19 mm external render (4 marks) Soffit 12 mm (4 marks) Fascia 25 mm (4 marks) Eaves gutter 100 mm (4 marks) Any 9 of the above details (4 marks each) (Sub-total 36 marks) Four typical dimensions (4 marks)
2014 · Paper 1 · Q5(a) · p.3
To a scale of 1:5, draw a vertical section through the portion of the roof at the ridge. Show the typical construction details from the top of the ridge to a level 150 mm below the collar ties. Include the ridge tile and three courses of tiles at the ridge. Label the roof components and include three typical dimensions. [Diagram: A traditional cut roof pitched at 45°, covered with concrete tiles on rafters.]
Marking scheme
Ridge tile (6 marks) Ridge vent (6 marks) Ridge board – 300 mm × 32 mm (6 marks) Tiles (6 marks) Battens – 50 mm × 30 mm (6 marks) Vapour barrier/vapour diffusion membrane (6 marks) Rafters – 200 mm × 50 mm (6 marks) Collar tie – 150 - 200 mm × 50 mm (6 marks) Insulation (6 marks) Plasterboard (6 marks) Labelling (6 marks) Any 6 of the above details (6 marks each) Sub-total (36 marks) Three typical dimensions (3 marks)