Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2015 · Paper 1 · Q5(a) · p.3
A traditional strip foundation supports the external wall of a dwelling house, as shown in the sketch. The external wall is of timber-frame construction, with a 100 mm concrete block outer leaf, a 50 mm cavity and a 200 mm insulated timber-frame inner leaf. The ground floor is an insulated concrete floor with a 20 mm quarry tile finish. To a scale of 1:5, draw a vertical section through the foundation, external wall and ground floor. Show the typical construction details from the bottom of the foundation, through the wall and ground floor to a level 400 mm above finished floor. Include the radon barrier and show four typical dimensions. [Sketch: A cross-section of a foundation, external wall (timber-frame with block outer leaf), and insulated concrete ground floor.] [Visual aid: Sketch: A cross-section of a foundation, external wall (timber-frame with block outer leaf), and insulated concrete ground floor.]
Marking scheme
External render – 19 mm (5 marks) Concrete block outer leaf - 100 mm (5 marks) 50 mm ventilated cavity (5 marks) Breather membrane and racking board, OSB/Plywood (5 marks) 200 mm timber stud (5 marks) 12.5 mm plasterboard (5 marks) Skirting board (5 marks) Concrete slab and 20 mm quarry tiles (5 marks) Floor insulation, 200 – 300 mm, with vertical insulation (5 marks) Radon barrier/DPM and Damp proof course (DPC) (5 marks) Hardcore and sand blinding (5 marks) Cavity fill and concrete insulation blocks (5 marks) Reinforced concrete foundation (5 marks) Footpath and hardcore (5 marks) Any 7 of the above details (5 marks each) (Sub-total 35 marks) Four typical dimensions (4 marks)