Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2026 · Paper 1 · Q5(a) · p.3
To a scale of 1:5, draw a vertical section through the external wall, concrete lintels, doorframe, and door. On your drawing show the typical construction details from 400 mm below to 400 mm above the lintels. Include three typical dimensions on your drawing. [Visual aid: Diagram: cross-section of an external wall with a doorframe and door.]
Marking scheme
External render (5 marks) Concrete block outer leaf (5 marks) Full fill insulated cavity with wall tie (5 marks) Concrete block inner leaf (5 marks) Internal plaster (5 marks) Cavity closer (5 marks) Stepped DPC (5 marks) Concrete lintels (5 marks) Thermally broken door frame (5 marks) Insulated door (5 marks) Airtightness (5 marks) Any 7 x 5 marks (35 marks) Three typical dimensions (3 x 1 mark) (3 marks) Draughting, accuracy, and scale (excellent, good, fair) (8, 6, 4 marks) (8 marks) Sub-total (11 marks)