2016 · Paper 1 · Q1(b) · p.2
On your drawing, show the typical design detailing to prevent the formation of a thermal bridge at the junction of the external wall and the floor. [Diagram: A cross-section of a dwelling house wall and foundation showing strip foundation, external wall, and ground floor construction.]
Marking scheme
Perimeter insulation/thermal blocks/cavity insulation overlaps with floor insulation/flexible seal between floor and wall (2 marks) Draughting, accuracy and scale (excellent, good, fair) (8, 6, 4 marks)
2016 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the strip foundation, the external wall and the ground floor. Show the typical construction details from the bottom of the foundation to a level 400 mm above finished floor. Show the position of the radon barrier and include four typical dimensions on your drawing. Show 1.0 metre width of floor. [Diagram: A cross-section of a dwelling house wall and foundation showing strip foundation, external wall, and ground floor construction.]
Marking scheme
100 concrete path / ground level (4 marks) D.P.C (4 marks) 100 mm concrete block outer leaf and 19 mm external render (4 marks) Full-fill cavity insulation (4 marks) Wall tie (4 marks) 100mm concrete block inner leaf and 13 mm internal plaster (4 marks) Skirting board (4 marks) 20 mm floating timber floor (4 marks) 150 mm concrete floor taped and seal between wall and floor (4 marks) 300 mm floor insulation (4 marks) D.P.M. /radon barrier (4 marks) Hardcore and sand blinding (4 marks) Concrete fill / foundation blocks (4 marks) Reinforced concrete foundation (4 marks) Any 9 of the above details (4 marks each) (Sub-total 36 marks) Four typical dimensions (4 marks)
2014 · Paper 1 · Q1(b) · p.2
On your drawing show one method to prevent the floor joists from twisting. [Diagram: A cross-section of a two-storey dwelling house wall and first floor, showing concrete block wall, cavity fill, plywood, joists, and floorboards.]
Marking scheme
Show one method to prevent the floor joists from twisting Bridging (2 marks) Draughting, accuracy and scale (excellent, good, fair) (8, 6, 4 marks)
2014 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the external wall and the first floor. The section should show the typical construction details from a level 300 mm below the plasterboard ceiling, through the wall, joists and floor, to a level 400 mm above the finished floor. Include four typical dimensions on your drawing. Show 1.0 metre width of floor. [Diagram: A cross-section of a two-storey dwelling house wall and first floor, showing concrete block wall, cavity fill, plywood, joists, and floorboards.]
Marking scheme
External render – 19 mm (4 marks) External leaf solid block – 100 mm (4 marks) 150 cavity full fill insulation (4 marks) Cavity ties (4 marks) Internal leaf solid block – 100 mm (4 marks) Internal plaster – 15 mm (4 marks) Skirting board (4 marks) Floating tongued and grooved hardwood floor (4 marks) Acoustic layer or adhesive layer for fixing floor boards (4 marks) Plywood deck – 20 mm (4 marks) Adhesive tape to wall and plywood (4 marks) Floor joists 225 × 40 mm (4 marks) Plasterboard taped to wall (4 marks) Plaster skim (4 marks) Any 9 of the above details (4 marks each) Sub-total (36 marks) Four typical dimensions (4 marks)