Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2019 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the fixed frame of the window and the external wall of the house. Show the typical construction detail from a level 400 mm below the window cill, through the window frame, up to a level 500 mm above the window head. [Visual aid: Diagram: cross-section of a window in an external wall.]
Marking scheme
External Timber Frame Wall: External render (4 marks), Concrete block (4 marks), Air space/Residual cavity (4 marks), Cavity closer (4 marks), Breather membrane (BM) (4 marks), Racking board (4 marks), 250 Stud/insulation (4 marks), Sheeting (4 marks), Air barrier membrane (ABM) (4 marks), Insulated service cavity (4 marks), Plasterboard/skim (4 marks). Triple Glazing: Concrete Window cill (4 marks), Wrap around DPC (4 marks), Frame cill - thermally broken (4 marks), Window board (4 marks), Glazing (Triple) (4 marks), Frame head -thermally broken (4 marks), Air -tight tapes @ head and cill (4 marks). Sheeting/Panel / Lintel: Larch Cladding (4 marks), Soffit (4 marks), Battens (4 marks), Counter battens (4 marks), DPC (4 marks), Batten for DPC (4 marks), Timber lintels (4 marks). Scale 4 marks: Drafting 4 marks: Excellent: 8, Good: 6, Fair: 4.