Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (8)
2026 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the proposed wall, given the construction has the following sequence and data: External render thickness 16 mm, External concrete block thickness 100 mm, Clear cavity width 60 mm, Timber stud thickness 250 mm, Oriented Strand Board (OSB) thickness 12 mm, Insulation between studs thickness 250 mm, Oriented Strand Board (OSB) thickness 12 mm, Plasterboard thickness 12.5 mm. Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W, Resistivity of external render (r) 2.170 m °C/W, Conductivity of concrete block (k) 1.440 W/m °C, Resistance of clear cavity (R) 0.440 m² °C/W, Conductivity of OSB (k) 0.130 W/m °C, Conductivity of insulation (k) 0.039 W/m °C, Conductivity of OSB (k) 0.130 W/m °C, Conductivity of plasterboard (k) 0.250 W/m °C, Resistance of internal surface (R) 0.130 m² °C/W. Note: The timber studs need not be considered in your calculations. [Visual aid: Image: sketch of an external wall design detail for a new house of timber frame construction.]
Marking scheme
U-value of external wall: Tabulation (3 marks); External surface resistance (3 marks); External render (3 marks); External concrete block (3 marks); Clear cavity (3 marks); OSB (3 marks); Insulation (3 marks); OSB (3 marks); Plasterboard (3 marks); Internal surface resistance (3 marks); Total resistance (3 marks); Calculation of U-value (w/m² °C or w/m²k) (3 marks).
2025 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the proposed wall, given the construction has the following sequence and data: External acrylic render thickness 8 mm External polystyrene insulation thickness 100 mm External render thickness 16 mm Hollow concrete block thickness 215 mm Insulation thickness 25 mm Plasterboard thickness 12.5 mm Internal skim coat thickness 3 mm Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W Conductivity of acrylic render (k) 0.670 W/m °C Conductivity of external insulation (k) 0.030 W/m °C Resistivity of external render (r) 2.170 m °C/W Resistance of hollow concrete block (R) 0.210 m² °C/W Conductivity of insulation (k) 0.037 W/m °C Conductivity of plasterboard (k) 0.160 W/m °C Resistivity of skim coat (r) 5.550 m °C/W Resistance of internal surface (R) 0.122 m² °C/W [Visual aid: Diagram showing a cross-section of an insulated wall with layers labelled]
Marking scheme
U-value of external wall (33 marks) - External surface resistance (3 marks) - Acrylic render (3 marks) - External insulation (3 marks) - External sand cement render (3 marks) - Hollow concrete block (3 marks) - Insulation (3 marks) - Plasterboard (3 marks) - Internal skim coat (3 marks) - Internal surface resistance (3 marks) - Total resistance (3 marks) - Calculation of U-value (w/m² °C or w/m²k) (3 marks)
2023 · Paper 1 · Q5(a) · p.4
An extension to a house has a highly insulated flat roof with a waterproof roof covering, as shown. Calculate the U-value of the roof, given the construction has the following sequence and data: Waterproof covering thickness 2 mm Roof insulation thickness 150 mm Plywood decking thickness 20 mm Clear cavity between roof joists thickness 200 mm Ceiling insulation thickness 50 mm Plasterboard thickness 12.5 mm Thermal data of the flat roof: Resistance of external surface (R) 0.048 m² °C/W Resistivity of waterproof covering (r) 6.250 m °C/W Conductivity of roof insulation (k) 0.022 W/m °C Conductivity of plywood (k) 0.130 W/m °C Resistance of clear cavity (R) 0.170 m² °C/W Conductivity of ceiling insulation (k) 0.022 W/m °C Conductivity of plasterboard (k) 0.250 W/m °C Resistance of internal surface (R) 0.122 m² °C/W [Visual aid: Image: Cross-section of a highly insulated flat roof.]
Marking scheme
U-value of flat roof. External surface resistance (3), Waterproof covering (3), Roof insulation (3), Plywood decking (3), Clear cavity (3), Ceiling insulation (3), Plasterboard (3), Internal resistance (3), Total resistance (3), Calculation of U-value (w/m² °C or w/m²k) (3). Total 30 marks.
2020 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the floor, given the construction has the following sequence and data: Hardwood flooring thickness 20 mm Sand/cement fine screed thickness 65 mm Floor insulation thickness 200mm Concrete floor slab thickness 150 mm Radon Barrier thickness 0.25 mm Sand blinding thickness 40 mm Hardcore thickness 200 mm Subsoil thickness 300 mm Thermal data of the ground floor: Resistance of internal top surface of floor (R) 0.104 m² °C/W Conductivity of hardwood flooring (k) 6.666 W/m °C Resistivity of fine screed (r) 1.410 m °C/W Conductivity of floor insulation (k) 0.022 W/m °C Conductivity of concrete floor slab (k) 1.280 W/m °C Conductivity of radon barrier (k) 0.250 W/m °C Conductivity of sand blinding (k) 0.160 W/m °C Conductivity of hardcore (k) 1.350 W/m °C Conductivity of subsoil (k) 1.600 W/m °C [Visual aid: Diagram showing a cross-section of a highly insulated solid concrete ground floor with hardwood finish.]
Marking scheme
[Diagram: U-value of concrete ground floor. Performance Criteria: Surface resistance (3 marks), Oak flooring (3 marks), Sand/cement fine screed (3 marks), Floor insulation (3 marks), Concrete floor slab (3 marks), Radon barrier (3 marks), Sand blinding (3 marks), Hardcore (3 marks), Subsoil (3 marks), Total resistance (R) (3 marks), Calculation of U- value (3 marks). Total for (a) is 11 points x 3 marks = 33 marks.]
2019 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the wall, given the construction has the following sequence and data: External render thickness 16 mm; Concrete block outer leaf thickness 100 mm; Clear cavity width 50 mm; Polystyrene insulation thickness 50 mm; Concrete block inner leaf thickness 100 mm; Internal plaster thickness 12 mm. Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W; Resistivity of external render (r) 2.170 m °C/W; Conductivity of concrete external blockwork (k) 1.440 W/m °C; Resistance of clear cavity (R) 0.170 m² °C/W; Conductivity of insulation (k) 0.037 W/m °C; Conductivity of concrete internal blockwork (k) 1.440 W/m °C; Resistivity of internal plaster (r) 6.250 m °C/W; Resistance of internal surface (R) 0.122 m² °C/W. [Visual aid: Diagram: cross-section of an external wall showing layers: external render, concrete block outer leaf, cavity, polystyrene insulation, concrete block inner leaf, internal plaster.]
Marking scheme
U-value of external wall. External surface resistance (3 marks). External render (3 marks). External blockwork (3 marks). Clear cavity (3 marks). Polystyrene insulation (3 marks). Internal blockwork (3 marks). Internal plaster (3 marks). Internal surface resistance (3 marks). Total resistance (3 marks). Calculation of U- value (3 marks). Total (10 points x 3 marks).
2018 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the uninsulated concrete ground floor, given the following data: Sand/cement fine screed thickness 50 mm Concrete floor slab thickness 100 mm Radon barrier thickness 0.25 mm Sand blinding thickness 40 mm Hardcore thickness 200 mm Subsoil thickness 300 mm Thermal data of the concrete ground floor: Resistance of internal top surface of floor (R) 0.104 m² °C/W Resistivity of fine screed (r) 0.710 m °C/W Conductivity of concrete floor slab (k) 1.280 W/m °C Conductivity of radon barrier (k) 0.250 W/m °C Conductivity of sand blinding (k) 0.160 W/m °C Conductivity of hardcore (k) 1.350 W/m °C Conductivity of subsoil (k) 1.600 W/m °C [Visual aid: Diagram: Cross-section of an uninsulated concrete ground floor with layers labelled and dimensions provided.]
Marking scheme
U-value of external wall: Tabulation (3 marks); Internal top surface resistance (3 marks); Fine screed (3 marks); Concrete floor slab (3 marks); Radon barrier (3 marks); Sand blinding (3 marks); Hardcore (3 marks); Subsoil (3 marks); Total resistance (3 marks); Calculation of U-value of ground floor (3 marks).
2017 · Paper 1 · Q5(a) · p.3
Calculate the U-value of the external wall, given the following data: External render thickness 16 mm Hollow concrete block thickness 215 mm Expanded polystyrene thickness 25 mm Plasterboard thickness 12.5 mm Thermal data of external wall of house: Resistance of external surface (R) 0.048 m² °C/W Resistivity of external render (r) 2.170 m °C/W Resistance of concrete block (R) 0.210 m² °C/W Conductivity of expanded polystyrene (k) 0.037 W/m °C Conductivity of plasterboard (k) 0.160 W/m °C Resistance of internal surface (R) 0.104 m² °C/W [Diagram: Cross-section of a 1970s external wall with insulation attached internally.]
Marking scheme
U-value of external wall (9 x 3 marks) Tabulation/methodology (3 marks) External surface resistance (3 marks) External render (3 marks) Hollow block (3 marks) Polystyrene (3 marks) Plasterboard (3 marks) Internal surface resistance (3 marks) Total resistance (3 marks) U-Value of external wall (1 mark for formula) (3 marks)
2014 · Paper 1 · Q5(a) · p.3
Using the following data, calculate the U-value of the insulated concrete ground floor: Concrete floor slab thickness 125 mm Extruded polystyrene insulation thickness 200 mm Damp proof membrane (DPM) thickness 0.30 mm Sand blinding thickness 30 mm Hardcore thickness 225 mm Thermal data of floor: Resistance of top surface of floor (R) 0.104 m² °C/W Conductivity of concrete (k) 0.160 W/m °C Conductivity of polystyrene insulation (k) 0.031 W/m °C Conductivity of damp proof membrane (DPM) (k) 0.450 W/m °C Conductivity of sand blinding (k) 0.160 W/m °C Conductivity of hardcore (k) 1.260 W/m °C [Visual aid: Diagram: cross-section of an insulated concrete ground floor showing layers and dimensions]
Marking scheme
Insulated concrete ground floor (9 points × 3 marks): Correct tabulation (3 marks); Surface resistance (3 marks); Concrete Floor (3 marks); Insulation (3 marks); DPM (3 marks); Sand (3 marks); Hardcore (3 marks); Total resistance (3 marks); U-Value (1 mark for formula) (3 marks).