Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2016 · Paper 1 · Q5(c) · p.3
It is proposed to upgrade the thermal properties of the above wall to meet the Passive House standard by fixing expanded polystyrene to the external surface. Given the thermal conductivity (k) of expanded polystyrene as 0.037 W/m °C, calculate the thickness of expanded polystyrene required to achieve a U-value of 0.15 W/m² °C. [Visual aid: Diagram: Cross-section of an external wall of timber frame construction, showing layers: external render, concrete block outer leaf, OSB sheeting, timber stud inner leaf with mineral wool insulation, and plasterboard. Thermal data for each layer is provided.]
Marking scheme
Upgrade to Passive House: U - value of 0.15 W/m² °C - Wall B (5 × 3 marks) Resistance for U-value of 0.15 W/m² °C (3 marks) Existing resistance from part (a) (3 marks) Difference in resistances (required resistance) (3 marks) Application of formula R = T/k (3 marks) Required thickness of insulation (3 marks) TOTAL 60