Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (2)
2019 · Paper 1 · Q5(c) · p.4
It is proposed to upgrade the thermal properties of the above wall, to meet the Passive House standard, by fixing expanded polystyrene to the external surface, as shown. Given the thermal conductivity (k) of expanded polystyrene as 0.031 W/m°C, calculate the thickness of expanded polystyrene required to achieve a U-value of 0.15 W/m² °C. [Visual aid: Diagram: cross-section of an external wall with expanded polystyrene added to the external surface.]
Marking scheme
Required thickness of insulation for U-value of 0.15W/m²K. Resistance for U- value for 0.15Wm²K (using R=1/U) (3 marks). Resistance from calculated U-value from part (a) (3 marks). Difference in resistances (required resistance) (3 marks). Application of formula R = T/k (3 marks). Required thickness of insulation (3 marks). Total (5 x 3 marks).
2017 · Paper 1 · Q5(b) · p.3
It is proposed to upgrade the thermal properties of the above wall, to meet the Passive House standard, by fixing expanded polystyrene to the external surface, as shown. Using the given thermal data at 5(a) above, calculate the thickness of expanded polystyrene required to achieve a U-value of 0.15 W/m² °C. [Diagram: Cross-section of an upgraded external wall with external insulation.]
Marking scheme
Wall A (6 x 3 marks) Formula U=1/R (3 marks) R value for 0.15 using R=1/U (3 marks) R value for calculated U-Value from part (a) (3 marks) Difference in resistances (required resistance) (3 marks) Application of formula R = T/k (3 marks) Required thickness of insulation (3 marks)