Past exam questions (6)
2024 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the wall, given the construction has the following sequence and data: Acrylic external render thickness 12 mm; External insulation thickness 150 mm; Concrete thickness 150 mm; Internal insulation thickness 50 mm; Internal plasterboard thickness 12.5 mm; Internal skim coat thickness 4 mm. Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W; Conductivity of acrylic external render (k) 0.670 W/m °C; Conductivity of external insulation (k) 0.030 W/m °C; Conductivity of concrete (k) 1.280 W/m °C; Conductivity of internal insulation (k) 0.030 W/m °C; Conductivity of plasterboard (k) 0.250 W/m °C; Resistivity of skim coat (r) 5.550 m °C/W; Resistance of internal surface (R) 0.122 m² °C/W. [Diagram: Cross-section of an external wall constructed using Insulated Concrete Formwork (ICF), showing layers of render, insulation, concrete, internal insulation, plasterboard, and skim coat.]
Marking scheme
Tabulation (3 marks). External surface resistance (3 marks). External render (3 marks). External insulation (3 marks). Concrete (3 marks). Internal insulation (3 marks). Internal plasterboard (3 marks). Internal skim coat (3 marks). Internal resistance (3 marks). Total resistance (3 marks). Calculation of U-value (w/m² °C or w/m²k) (3 marks). Total (33 marks).
2022 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the wall, given the construction has the following sequence and data: Acrylic external render thickness 8 mm; External insulation thickness 150 mm; External scratch coat thickness 10 mm; Concrete block thickness 215 mm; Internal plaster thickness 12 mm. Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W; Conductivity of acrylic external render (k) 0.670 W/m °C; Conductivity of external insulation (k) 0.031 W/m °C; Conductivity of external scratch coat (k) 2.170 W/m °C; Conductivity of concrete blockwork (k) 1.440 W/m °C; Resistivity of internal plaster (r) 4.550 m °C/W; Resistance of internal surface (R) 0.122 m² °C/W. [Diagram: A cross-section of an external wall showing layers: acrylic external render, external insulation, external scratch coat, concrete block, internal plaster.]
Marking scheme
U-value of external wall (10 x 3 marks) Tabulation/methodology (3 marks) External surface resistance (3 marks) Acrylic render (3 marks) External insulation (3 marks) External scratch coat (3 marks) Concrete blockwork (3 marks) Internal plaster (3 marks) Internal resistance (3 marks) Total resistance (3 marks) Calculation of U-value (w/m² °c or w/m²k) (3 marks)
2021 · Paper 1 · Q5(a) · p.4
Calculate the U-value of the wall, given the construction has the following sequence and data: External brick thickness 100 mm; Clear cavity width 50 mm; Orientated strand board (OSB) thickness 9 mm; Timber stud thickness 175 mm; Cellulose insulation between studs thickness 175 mm; Orientated strand board (OSB) thickness 9 mm; Plasterboard thickness 12.5 mm. Thermal data of the external wall: Resistance of external surface (R) 0.048 m² °C/W; Resistivity of external brick (r) 1.300 m °C/W; Resistance of clear cavity (R) 0.440 m² °C/W; Conductivity of OSB (k) 0.130 W/m °C; Conductivity of cellulose insulation (k) 0.039 W/m °C; Conductivity of OSB (k) 0.130 W/m °C; Conductivity of Plasterboard (k) 0.250 W/m °C; Resistance of internal surface (R) 0.130 m² °C/W. Note: The timber studs need not be considered in your calculations. [Diagram: A cross-section of an external wall construction for a timber frame house, showing layers of brick, cavity, OSB, timber stud, insulation, OSB, and plasterboard.]
Marking scheme
U-value of the timber frame wall: External surface resistance (3 marks); External brick (3 marks); Air cavity (3 marks); Orientated strand board (3 marks); Cellulose insulation (3 marks); Orientated strand board (3 marks); Plasterboard (3 marks); Internal resistance (3 marks); Total resistance (3 marks); Calculation of U-value (w/m² °c or w/m²k) (3 marks). (b) Required thickness of insulation for U-value of 0.15 W/m² °c: Resistance for U- value for 0.15 W/m² °c (using R=1/U) (3 marks); Resistance from calculated U-value from part (a) (3 marks); Difference in resistances (required resistance) (3 marks); Application of formula R = T/k (3 marks); Required thickness of insulation in mm. (3 marks). (c) Moisture control and vapour control layers in timber frame construction: Notes / discussion (8 marks); Sketch (7 marks).
2016 · Paper 1 · Q5(a) · p.3
Calculate the U-value of the above external wall. [Visual aid: Diagram: Cross-section of an external wall of timber frame construction, showing layers: external render, concrete block outer leaf, OSB sheeting, timber stud inner leaf with mineral wool insulation, and plasterboard. Thermal data for each layer is provided.]
Marking scheme
U-value of external wall (10 × 3 marks) External plaster (3 marks) External block (3 marks) OSB Racking Board (3 marks) Mineral Wool Insulation (3 marks) Plasterboard (3 marks) Cavity (3 marks) External surface resistance (3 marks) Internal surface resistance (3 marks) Total resistance (3 marks) U-value of external wall (1 mark for formula) (3 marks)
2015 · Paper 1 · Q5(b) · p.3
Using the U-value obtained at 5(a) and the data given below, calculate the cost of heat lost annually through the external walls of each of the following: • the new house - as specified at 5(a) above and • an existing house that complies with current Building Regulations, having a U-value of 0.21 W/m² °C for the walls. Data for both houses: Area of external wall of each house 150 m² Average internal temperature 20 °C Average external temperature 6 °C Heating period 8 hours per day, every day for 35 weeks per annum Cost of oil 95 cent per litre Calorific value of oil 37350 kJ per litre 1000 watts 1kJ per second.
Marking scheme
Annual heat loss (10 points x 2 marks): New house: Heat loss formula and calculation (2 marks), Heating duration for one year (2 marks), kJ calculation for one year (2 marks), Litres of oil for one year (2 marks), Annual cost of heat loss (2 marks). Existing house: Heat loss calculation (2 marks), Heating duration for one year (2 marks), kJ calculation for one year (2 marks), Litres of oil for one year (2 marks), Annual cost of heat loss (2 marks).
2015 · Paper 1 · Q5(a) · p.3
Using the following data, calculate the U-value of the external wall of a new dwelling house. The wall is of concrete block construction, with a 250 mm cavity. The cavity is a full-fill insulated cavity, with polystyrene bead insulation as shown. Specification of external wall: External render thickness 16 mm Concrete block outer leaf thickness 100 mm Cavity width 250 mm Concrete block inner leaf thickness 100 mm Internal plaster thickness 12 mm Thermal data of external wall: Resistance of external surface (R) 0.048 m² °C/W Conductivity of external render (k) 0.720 W/m °C Conductivity of concrete blocks (k) 1.440 W/m °C Conductivity of polystyrene bead (k) 0.031 W/m °C Conductivity of internal plaster (k) 0.220 W/m °C Resistance of internal surface (R) 0.122 m² °C/W [Visual aid: Diagram showing a cross-section of an external wall with insulation]
Marking scheme
Insulated concrete ground floor (10 points x 3 marks): Tabulation / methodology (3 marks), External surface resistance (3 marks), External render (3 marks), External block (3 marks), Polystyrene bead (3 marks), Internal block (3 marks), Internal plaster (3 marks), Internal surface resistance (3 marks), Total resistance (3 marks), U-value (1 mark for formula) (3 marks).