Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (4)
2026 · Paper 1 · Q1(a) · p.2
To a scale of 1:10, draw a vertical section through one half of the roof structure, from just below eaves up to the ridge. Show one external wall and one rafter length. Include the typical construction details from 600 mm below the ceiling joists up to the ridge, and include three courses of slate at eaves. Include four typical dimensions. [Visual aid: Diagram: sketch of a dwelling house with a traditional slated cut roof.]
Marking scheme
External Wall – typical detailing: External & internal render (4 marks); Cavity wall - 100 mm external and internal leaf (4 marks); Wall ties (4 marks); 250 mm full-fill insulated cavity (4 marks); Cavity closer (4 marks); 100 mm × 75 mm wallplate/s. (4 marks). Roof Structure - typical detailing: 200 mm x 50 mm rafters @ 400 mm centres (4 marks); Ceiling joist @ 400 mm centres (4 marks); 225 mm × 75 mm purlin (4 marks); Strut supporting the purlin (4 marks); Hanger (4 marks); Collar tie at each couple or @ 1200 mm centres (4 marks); Ridge-board (4 marks); Plasterboard and 350 mm insulation laid in 3 layers. (4 marks). Eaves detail – typical detailing: Tilting fillet (4 marks); Facia board, soffit, and gutter (any 2) (4 marks); 25 mm facia ventilator and 50 mm proprietary eaves ventilator (4 marks); Wind tightness barrier (4 marks); Breather membrane laid over roof rafters (4 marks); 50 mm x 30 mm slating batten (4 marks); 3 courses of slates. (4 marks). Four typical dimensions: Scale - 4 marks, Drafting - 4 marks (8 marks total).
2020 · Paper 1 · Q1(a) · 25 marks · p.2
The sketch shows a dwelling house with a traditional slated cut roof. The roof has a pitch of 30° and flush eaves as shown. The internal span of the house is 6.0 metres and the roof is highly insulated. The external wall of the house is a 215 mm single leaf wall of solid concrete block construction with 200 mm external insulation and acrylic render external finish. Insulated plasterboard is fixed to the underside of the ceiling joists. A 50 mm service cavity is also provided at the internal surface of the wall. To a scale of 1:10, draw a vertical section through one half of the roof structure from just below eaves up to ridge. Show one external wall and one rafter length. Include the typical construction details from 600 mm below the ceiling joists up to the ridge and include three courses of slate at eaves. Include four typical dimensions of the roof structure. [Visual aid: Sketch of a dwelling house with a slated cut roof.]
Marking scheme
[Diagram: Vertical section through one half of the roof structure showing External Wall, Roof structure, and Eaves detail. Performance Criteria and Maximum Mark columns list specific components for each section. External Wall: External acrylic render (4 marks), External insulation (4 marks), Concrete block on flat (4 marks), Internal plaster / Air barrier membrane (4 marks), Insulated service cavity (4 marks), Plasterboard/skim (4 marks). Roof structure: Wallplate 100 x 75 (4 marks), Rafter 200 x 50 (4 marks), Ceiling joist (4 marks), Purlin 225 x 75 (4 marks), Strut (4 marks), Hanger (4 marks), Collar tie (4 marks), Ridgeboard (4 marks), Insulation (4 marks). Eaves detail: Facia and gutter (4 marks), Ventilation (4 marks), Breather membrane (4 marks), Slating batten 50 x 30 (4 marks), 3 courses of slates (4 marks). Four typical dimensions (1 x 4 marks) (4 marks). Scale - 4 marks, Drafting - 4 marks. Excellent: 8, Good: 6, Fair: 4. Total for (a) is 60 marks.]
2015 · Paper 1 · Q7(b) · p.4
Include on you drawing, best practice design detailing to ensure ventilation of the roof structure. [Visual aid: Diagram of a roof structure cross-section]
2015 · Paper 1 · Q7(a) · p.4
To a scale of 1:10, draw a vertical section through one half of the roof structure from eaves up to ridge, showing one external wall and one rafter length. Show the typical construction details from 500 mm below the floor joists up to the ridge and include three courses of slate at eaves. Include four typical dimensions of the roof structure. [Visual aid: Diagram of a roof structure cross-section]
Marking scheme
Vertical section through roof structure - attic: Any 10 points x 4 marks (Drawing 3, Annotation 1). Wall: 400 mm external wall (4 marks), Full-fill cavity insulation (4 marks), Internal and external plaster/render (4 marks), Cavity closer (4 marks), 100mm load-bearing centre wall (4 marks). Roof: Wallplate (4 marks), Rafter (4 marks), Insulated slab to underside of rafter (4 marks), Vertical purlin (4 marks), Strut and collar (4 marks), Breather membrane and battens (4 marks), Counter battens (4 marks), Slates (4 marks), Fascia/soffit/gutter – (any 2) (4 marks), Ridge board (4 marks), Ceiling joist and 25mm tongue-and-groove floor boards (4 marks). 4 typical dimensions (4 marks). Scale and Draughting: Draughting 4 marks, Scale 4 marks (excellent 4, good 3, fair 2) (8 marks). (b) Best practice design detailing to ensure ventilation (8 marks): Two design details for ventilation - eaves and roof/ridge (4 + 4 marks) (8 marks). TOTAL 60 marks.