2023 · Paper 1 · Q1(a) · p.2
The sketch shows a dwelling house with a roof constructed using prefabricated trussed rafters. The tiled roof has a pitch of 30° and an internal span of 5.6 metres. The external wall is of timber frame construction with an external rendered concrete block leaf. The internal timber frame is 250 mm × 50 mm. A 50 mm service cavity is also provided at the internal surface. The roof is highly insulated at ceiling joist level. To a scale of 1:10, draw a vertical section through one half of the roof structure from eaves up to the ridge. Show one external wall and one rafter length. Include the typical construction details from 600 mm below the ceiling joist up to the ridge and include three courses of tiles at eaves. [Visual aid: Sketch of a dwelling house with a tiled roof.]
Marking scheme
External timber frame wall (5 x 4 marks): External render (4), Concrete block + Tie (4), Firestopping / cavity closer (4), Air space / residual cavity (4), Breather membrane (4), Racking board (4), Stud (4), Insulation (4), Air barrier membrane (4), Insulated service cavity (4), Plasterboard / skim (4). Roof structure (3 x 4 marks): Prefabricated roof truss - rafter / ceiling joist / hanger/ strut (Any two) (4), Gang nail plates & truss fixing (4), Attic insulation (4), Insulated plasterboard - ceiling (4), Air tightness tape - junction wall + ceiling (4), Air-barrier membrane at ceiling (4). Eaves detail (4 x 4 marks): Fascia / soffit / gutter (Any two) (4), Tilting fillet (4), Ventilation (4), Wind tightness barrier (4), Roof breather membrane (4), Counter battens (4), Tiling battens (4), Three courses of concrete tiles (4). Scale - 4 marks, Drafting - 4 marks. Total 8 marks.
2014 · Paper 1 · Q1(a) · p.2
To a scale of 1:10, draw a vertical section through one external wall and one rafter length. Show the typical construction details from 400 mm below the ceiling joists, through the external wall and eaves, up to ridge level. Include the ventilation path to the roof and show three courses of slate at eaves. Include three typical dimensions of the roof structure. [Visual aid: Sketch of a roof section with labels]
Marking scheme
Wall details: Double headplate 200 × 50 mm (4 marks); Vertical stud framework 200 × 50 @ 400 mm centres (4 marks); Insulated service cavity 60 mm (4 marks); Vapour barrier to ceiling and wall - joints sealed and taped (4 marks); 12.5 mm gypsum plasterboard and hardwall skim finish (4 marks); Airtight tape at wall and ceiling junction to ensure airtightness (4 marks); Insulation 200 mm (4 marks); Racking board 12 – 20 mm OSB or plywood with taped joints (4 marks); Breather membrane with taped joints (4 marks); Vapour diffusion cavity 50 – 100 mm (4 marks); Fireproof cavity closer (4 marks); Stainless steel wall ties (4 marks); 100 concrete block outer leaf (4 marks); 15 mm render – 2 coats (4 marks). Typical roof details - Prefabricated Truss Rafter: Battens 50 × 40 mm (4 marks); Breather membrane sealed and taped (4 marks); Prefabricated roof trusses at 400 - 600 mm centres - rafters and ceiling joists 180 × 50 mm (4 marks); 150 × 50 mm struts secured with nail plates (4 marks); 300 - 600 mm insulation to ceiling (4 marks); Gypsum plasterboard to ceiling with vapour barrier on warm side of insulation (4 marks); Fascia, soffit & gutter (any 2) (4 marks). Scale and Drafting (8 marks); Three typical dimensions of roof structure (3 marks); Three courses of slate at eaves (3 marks); Ventilation path at eaves (3 marks); (b) Design detail to ensure airtightness (3 marks).