Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2018 · Paper 1 · Q5(c) · p.4
It is proposed to redesign the above floor and upgrade its thermal properties to meet the Passive House standard by including expanded polystyrene in the design of the floor. Given the thermal conductivity (k) of expanded polystyrene as 0.037 W/m °C, calculate the thickness of expanded polystyrene required to achieve a U-value of 0.15 W/m² °C. [Visual aid: Diagram: Cross-section of an uninsulated concrete ground floor with layers labelled and dimensions provided.]
Marking scheme
Required thickness of insulation for U-value of 0.15W/m²K: Resistance for U- value for 0.15Wm²K using R=1/U (3 marks); Resistance from calculated U-value from part (a) (3 marks); Difference in resistances (required resistance) (3 marks); Application of formula R = T/k (3 marks); Required thickness of insulation (3 marks).