Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2020 · Paper 1 · Q7(a) · p.5
To a scale of 1:5, draw a vertical section through the ground floor, hearth and chimney. Show the typical construction details from 350 mm below the finished floor to a level 300 mm above the top of the cast iron flue from the stove and include the connection to the flue liner in the chimney. Include three typical dimensions on your drawing. [Visual aid: Illustration of a wood-burning stove inset into a chimney breast.]
Marking scheme
[Diagram: Vertical section through ground floor, hearth with a stove and chimney. Performance Criteria: Ground Floor (200 mm Internal wall - 5 marks; Concrete floor / subfloor - 5 marks; Floor insulation - 5 marks; Concrete screed - 5 marks; Radon /DPM - 5 marks; Insulated block - 5 marks; Airtightness - 5 marks; 20 mm Hardwood floor - 5 marks; Plaster - 5 marks). Hearth / Stove / Chimney (Hearth - 5 marks; Stove - 5 marks; 150 mm Cast iron flue - 5 marks; Lintel / flue gatherer - 5 marks; Chimney blockwork - 5 marks; Metal flue gatherer - 5 marks; Flue liners - 5 marks; Lime sand fill / vermiculite - 5 marks; Internal plaster - 5 marks). Three typical dimensions (3 x 1 mark) (3 marks). Scale and drafting marks (Excellent - 8, Good - 6, Fair - 4). Total for (a) is 9 x 5 marks + 3 marks + 8 marks = 56 marks.]