Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (1)
2021 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the centre of the door, the external wall and the ground floor. Show the typical construction details from the bottom of the strip foundation to a level 400 mm above finished floor level. Show a width of 1.0 metre on each side of the door. [Diagram: An external wooden door with vertical sheeting, a 400 mm concrete block wall with insulated cavity, and a solid concrete ground floor with hardwood finish.]
Marking scheme
Foundation, external wall and level entrance: R.C. foundation (4 marks); Blockwork - dead work (4 marks); Vertical insulation - thermal break (4 marks); Entrance substructure (4 marks); Level concrete surface (4 marks). Solid ground floor: Compacted hardcore (4 marks); Sand blinding (4 marks); Radon barrier / DPM (4 marks); Floor insulation (4 marks); Concrete floor / subfloor (4 marks); 20 mm hardwood flooring (4 marks). Door threshold and door: Drainage channel (4 marks); Concrete threshold and wrap around DPC / Proprietary insulated door threshold (4 marks); 15 mm upstand or 15° (4 marks); Airtight tape at threshold (4 marks); External door / vertical sheeting (4 marks); Door insulation (4 marks). Scale - 4 marks Drafting - 4 marks. Excellent - 8 marks, Good - 6 marks, Fair - 4 marks. (b) Design detailing to prevent a thermal bridge at threshold: Design detailing to prevent a thermal bridge (4 marks).