2022 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the external wall of the dining area, the flat roof and the rear wall of the house. Show the typical construction details from a level 300 mm below the wallplate of the dining area wall, through the flat roof, to a level 400 mm above the abutment of the roof and the rear wall of the house. [Diagram: A house with a flat roof extension. The extension is 1.6m from the rear wall. The flat roof has a waterproof membrane, 150mm rigid insulation, plywood decking, supported on 200mm x 50mm roof joists. Insulated plasterboard is fixed to the underside of the joists. The external wall is a 450mm rendered concrete block wall with a full-fill cavity.]
Marking scheme
External wall & eaves - typical detailing (4 marks each) • External & internal render • Cavity wall & wall ties - 100 mm external and internal leaf • 250 mm Full-fill insulated cavity • Cavity closer • 100 mm x 75 mm Wallplate • Fascia / soffit / gutter (any 2) Flat roof - typical detailing (4 marks each) • Waterproof membrane • 150 mm Roof insulation • Breather membrane • OSB / plywood decking • Firing pieces (1:40 slope) • 200 mm x 50 mm Roof joists • Air-barrier / Airtightness membrane • Insulated plasterboard (50 mm insulation + 12.5 mm plasterboard) Rear external wall & abutment- typical detailing (4 marks each) • External & internal render • Cavity wall & wall ties - 100 mm external and internal leaf • 100 mm x 75 mm Concrete lintels • Cavity closer • 200 mm x 50 mm Wallplate & metal hanger • Tilting fillet & lead flashing • Stepped DPC. Scale - 4 marks, Drafting - 4 marks [Excellent 8, Good 6, Fair 4] (b) Design detailing to prevent a thermal bridge at abutment (4 marks)
2016 · Paper 1 · Q1(b) · p.2
Show on your drawing the design detailing to prevent the ingress of water at the junction of the flat roof and the main wall of the house. [Visual aid: Diagram: a house with a front porch projecting from the external wall.]
2016 · Paper 1 · Q1(a) · p.2
To a scale of 1:5, draw a vertical section through the porch, showing the external wall, the flat roof and the window of the porch. Show the typical construction details from a level 300 mm below the fixed frame of the porch window, through the walls, the window head, lintels and flat roof to a level 400 mm above the abutment of the flat roof and the front wall of the house. Include four typical dimensions. [Visual aid: Diagram: a house with a front porch projecting from the external wall.]
Marking scheme
Timber flat roof, external walls and window (Drawing 3, Annotation 1) (11 × 4 marks) • Lead flashing (4 marks) • Bituminous felt (4 marks) • Eaves batten/drip (4 marks) • Plywood decking (4 marks) • Tilting fillet (4 marks) • Counter battens/ventilation (4 marks) • Breather membrane (4 marks) • Joist & roof insulation (4 marks) • Wallplate (4 marks) • Vapour control layer (4 marks) • Hanger to main wall/metal hangers (4 marks) • Insulated plasterboard (4 marks) • Fascia / Soffit / Gutter (any 2) (4 marks) • Cavity wall & wall ties (4 marks) • Cavity closer (4 marks) • Wall insulation (4 marks) • Internal and external renders (4 marks) • Stepped DPC in cavity (4 marks) • Lintels (4 marks) • Window frame - thermally broken (2 marks without thermal break) (4 marks) • Triple-glazed unit (4 marks) • Airtightness tapes to ceiling and windows (4 marks) Four typical dimensions (4 marks) Scale (4 marks) Drafting (4 marks) (Excellent, Good, Fair) (4, 3, 2) Design detail to prevent the ingress of water (4 marks) TOTAL 60