Study notes
No notes have been generated for this topic yet. Open the topic page online and click Generate notes first.
Past exam questions (2)
2024 · Paper 1 · Q1(a) · p.2
To a scale of 1:10, draw a vertical section through the entrance porch showing the external wall of the porch, the sloping roof, and the front wall of the house. Include the typical construction details of the porch from a point 300 mm below the wall plate, through the sloping rafters, to a level 350 mm above the abutment of the porch roof with the front wall of the house. Show three courses of slate at eaves. [Visual aid: Drawing of a house with an entrance porch]
Marking scheme
External wall and eaves: Larch cladding rain screen (4 marks), Battens / counter battens (4 marks), Cavity wall blockwork & low conductivity wall ties (4 marks), Full-fill insulation (4 marks), Cavity closer (4 marks), Wallplates (4 marks), Skim / plaster (4 marks). Lean-to roof: Fascia / soffit / gutter (Any two) (4 marks), Three courses of slates (4 marks), Slating battens 50 x 30 mm @ 400 mm centre / counter battens (4 marks), Roof breather membrane (4 marks), Ventilation (4 marks), Roof rafter & insulation (4 marks), Air barrier membrane & airtightness taping (4 marks), Insulated plasterboard (50 mm insulation + 12.5 mm plasterboard) (4 marks). Front wall of house and abutment: External & internal render (4 marks), Full-fill cavity wall blockwork & wall ties (4 marks), Concrete lintels (4 marks), Cavity closer (4 marks), Rafter support (4 marks), Stepped DPC (4 marks), Lead flashing (4 marks). Scale - 4 marks, Drafting - 4 marks. Excellent (8 marks), Good (6 marks), Fair (4 marks). [Drawing of a vertical section through a lean-to roof and external walls of a house, showing all the listed components.]
2024 · Paper 1 · Q7(a) · p.5
To a scale of 1:5, draw a vertical section through the external wall, window, and first floor. Show the typical construction details from a level 200 mm below the head of the window, to a level 200 mm above the finished first floor. [Diagram: A window fitted in the external wall of a two-storey dwelling house. Wall is timber frame construction with external rendered concrete block leaf. Internal timber frame leaf, service cavity, first floor joists, OSB deck, wooden joists, and plasterboard ceiling are shown.]
Marking scheme
External wall: External render (4 marks), Concrete block (4 marks), Air space / residual cavity (4 marks), Breather membrane (4 marks), OSB Racking board (4 marks), 250 x 50 mm Stud and insulation (4 marks), Air barrier (4 marks), Insulated service cavity (4 marks), Plasterboard / skim (4 marks). Window Frame: Concrete lintel (4 marks), Timber lintel (4 marks), Fire stop / cavity closer (4 marks), Stepped DPC (4 marks), Thermally broken frame (4 marks), Glazing (Triple) (4 marks), Airtightness tape - window frame head (4 marks). Floor: Joist support at wall (4 marks), Tongued and groove flooring / skirting board (4 marks), OSB decking (4 marks), 225 x 50 mm Joist (4 marks), Sound insulation (4 marks), Plasterboard ceiling (4 marks). Scale - 4 marks, Drafting - 4 marks. Excellent (8 marks), Good (6 marks), Fair (4 marks). [Drawing of a vertical section through a timber frame wall, window, and first floor joist, showing all listed components.]